KAJIAN KAPASITAS SALURAN DRAINASE DI JALAN MELATI KOTA ENDE, NUSA TENGGARA TIMUR

EDUARDUS SEFRADUS SINAR, TENDA (2022) KAJIAN KAPASITAS SALURAN DRAINASE DI JALAN MELATI KOTA ENDE, NUSA TENGGARA TIMUR. Skripsi thesis, UNIVERSITAS FLORES.

[img] Text (COVER)
COVER SKRIPSI.pdf

Download (723kB)
[img] Text (BAB I)
BAB 1.pdf
Restricted to Registered users only

Download (478kB) | Request a copy
[img] Text (BAB II)
BAB 2.pdf
Restricted to Registered users only

Download (1MB) | Request a copy
[img] Text (BAB III)
BAB 3.pdf
Restricted to Registered users only

Download (512kB) | Request a copy
[img] Text (BAB IV)
BAB 4.pdf
Restricted to Registered users only

Download (992kB) | Request a copy
[img] Text (BAB V)
BAB 5.pdf
Restricted to Registered users only

Download (117kB) | Request a copy
[img] Text (LAMPIRAN)
LAMPIRAN.pdf
Restricted to Registered users only

Download (1MB) | Request a copy

Abstract

ABSTRAK EDUARDUS SEFRADUS SINAR TENDA. Kajian Kapasitas Saluran Drainase Di Jalan Melati, Kota Ende (dibimbing oleh Marselinus Y. Nisason, S.T.,M.T dan Yohanes Meo, S.T.,M.T) Dikala musim hujan wilayah di Jalan Melati, Kota Ende sering digenangi banjir. . Metode penelitian yang digunakan yaitu metode pengumpulan dan analisa data Curah hujan, Debit banjir rencana dan kapasitas saluran. Dari hasil penelitian data curah hujan diambil dalam kurun waktu 10 tahun terakhir, Data curah hujan Tahun 2011 = 96,1 mm, Tahun 2012 = 89,9 mm, Tahun 2013 = 98,6 mm, Tahun 2014 = 80,72 mm, Tahun 2015 = 87,64 mm, Tahun 2016 = 200,17 mm, Tahun 2017 = 141,9 mm, Tahun 2018 = 129,95 mm, Tahun 2019 = 135,08 mm, Tahun 2020 = 123,43 mm Dari hasil penelitian nilai debit banjir rencana untuk periode 2 tahun diketahui bahwa saluran Melati Atas Kiri Sekmen 1 =0.424 m3 /det, Melati Atas Kiri Sekmen 2=0.680 m3 /det Melati Atas Kiri Sekmen 3 =1,044 m3 /det Melati Atas Kanan Sekmen 1 = 0,197 m3 /det,Melati Atas Kanan Sekmen 2 = 0,222 m3 /det Melati Bawak Kiri =1,341 m3 /det dan Melati Bawah Kanan = 5,582 m3 /det. Dari hasil penelitian nilai debit banjir rencana untuk periode 5 tahun diketahui bahwa saluran Melati Atas Kiri Sekmen 1 =0.549 m3 /det, Melati Atas Kanan Sekmen 1 = 0,255 m3 /det,Melati Atas Kanan Sekmen 2 = 0,287 m3 /det Melati Bawak Kiri =1,763 m3 /det dan Melati Bawah Kanan = 57,224 m3 /det. Dari hasil penelitian nilai debit banjir rencana untuk periode 10 tahun diketahui bahwa saluran Melati Atas Kiri Sekmen 1 =1,579 m3 /det Melati Atas Kanan Sekmen 1 = 0,298 m3 /det,Melati Atas Kanan Sekmen 2 = 0,335 m3 /det Melati Bawak Kiri =2,025 m3 /det dan Melati Bawah Kanan = 8,430 m3 /det. Dari hasil perhitungan nilai Q kapasitas tampung drainase pada kondisi eksisting diketahui bahwa, saluran Melati Atas Kiri Sekmen 1 =2,379 m3 /det, Melati Atas Kiri Sekmen 2=4,170 m3 /det Melati Atas Kiri Sekmen 3 =4,827 m3 /det, Melati Atas Kanan Sekmen 2 = 2,400 m3 /det Melati Bawak Kiri =4,099 m3 /det dan Melati Bawah Kanan = 4,099 m3 /det. Dari hasil perhitungan nilai Q kapasitas tampung drainase pada kondisi eksisting diketahui bahwa, drainase ada yang mampu menampung besarnya debit curah hujan dan Ada juga yang tidak mampu menampung besarnya debit curah hujan.

Item Type: Thesis (Skripsi)
Uncontrolled Keywords: Kata kunci : analisa frekuensi, metode rasional, drainase eksisting